Durajoint Waterstop Durajoint Forming Durajoint Rebar Supports Durajoint Mesh Supports Durajoint Transportation Durajoint Prestressed Durajoint Specialty Products

EXPAND-Tite



Durajoint ®
Concrete Accessories
10426 Industrial Drive
Garrettsville, Ohio 44231

Toll Free:
1-888-833-8308

Direct:
1-330-527-4308

Technical Assistance:
1-888-833-8308

Fax:
1-330-527-2440

Home / Contact / Msds / About Us
Poured-In-Place Concrete Structures Precast Concrete Structure
1. Carefully brush-off all dust and debris and apply a coat of an appropriate EXPAND-Tite primer to the area where the EXPAND-Tite Waterstop is to be placed on the standing structural member. 1. Carefully brush off all loose dust and dirt
2. Using moderate hand pressure, with the heel of the hand, press a continuous bead of EXPAND-Tite Waterstop firmly into position on the standing structure. Check to be certain that the sealant has bonded to the primed area. 2. Always use an appropriate EXPAND-Tite primer product on both mating surfaces.
3. Peel the protective backing from the exposed side of the EXPAND-Tite Waterstop. Knead the overlapped ends together to form a continuous, uninterrupted gasket. 3. Apply EXPAND-Tite Waterstop to lap joint or tongue & groove joint in the location where the maximum compression is expected to occur.
4. Pour the mating structural member into position 4. Using moderate hand pressure, with the heel of the hand, press a continuous bead of EXPAND-Tite Waterstop firmly into position on the structure
5. Remove the protective backing and knead overlapped ends together to form a continuous, uninterrupted gasket.
6. Assemble mating precast structures into position.